Thanks to the onboard NA556 dual precision timer from Texas Instruments and the G6D-ASI power PCB relay from Omron, the FLICKER click can control loads up to 5A, 250 VAC/30 VDC at a predefined time interval.

The on/off period can last from 0.1 to 6 seconds, that can be set by the two ON/OFF onboard potentiometers. The external load can be connected to the board through the screw terminal. FLICKER click runs on 5V power supply and it communicates with the MCU over RST pin.

flicker-click-page.png

DO NOT TOUCH THE BOARD WHILE THE EXTERNAL POWER SUPPLY IS ON!

Note: FLICKER click has exposed pins/pads. To stay safe take precaution when applying high voltage to the click. The click is to be used by trained personnel only when applying high voltage.


Applications

FLICKER click is the perfect, simple solution if you need to turn a device on and off at specific time intervals, like blinking LED commercials, alarm system lights, or any other signalling lights.

Specifications

Type Relay
Applications FLICKER click is the perfect, simple solution if you need to turn a device on and off at specific time intervals, like blinking LED commercials, alarm system lights, or any other signalling lights
On-board modules NA556 dual precision timer from Texas Instruments and the G6D-ASI power PCB relay from Omron
Key Features G6D-ASI power PCB relay, Max. loads up to 5 A, 250 VAC/30 VDC, Min. permissible load 10 mA at 5 VDC, Contact resistance 100 mΩ max
Key Benefits Screw terminal for external load
Interface GPIO
Input Voltage 5V,5V
Compatibility mikroBUS
Click board size L (57.15 x 25.4 mm)

Pinout diagram

This table shows how the pinout on FLICKER click corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

NotesPinMikrobus logo.pngPinNotes
  NC 1 AN PWM 16 NC  
Turns the NE556 on and off FON 2 RST INT 15 NC  
  NC 3 CS RX 14 NC  
  NC 4 SCK TX 13 NC  
  NC 5 MISO SCL 12 NC  
  NC 6 MOSI SDA 11 NC  
  NC 7 +3.3V +5V 10 +5V +5V power supply
Ground GND 8 GND GND 9 GND  

Onboard PCB relay

Maximum switching capacity of the G6D-ASI PCB relay is 1250VA at 150W. Maximum contact resistance is 100 mΩ.

Potentiometers

The two potentiometers (P1 and P2) set the switching on and off time.

DesignatorNameTypeDescription
P1   Potentiometer Adjusting Ton
P2   Potentiometer Adjusting Toff
CN1 Terminal block Connector for connecting the device

Maximum ratings

DescriptionMinTypMaxUnit
Contact resistance     100m Ω
Operate time     10m s
Ambient temperature -25   70 C
Operating current     5 A
Operating voltage     250 VAC

Programming

This code snippet configures required port E as digital, sets pins 1 and 2 as input and enters an infinite loop. While in an infinite loop, use potentiometers P1 and P2 to adjust the ON / OFF time period.

  • Supply voltage within range of 5 – 15 V.
  • Maximum output current detected : 225 mA.
  • Usable on : ARM, PIC, PIC32, AVR and FTDI compilers.
 1
2    void main()
3     {
4       ANSELE = 0;            // Configure PORTE pins as digital
5       TRISE2_bit = 1;        // Set RE2 pin as input
6       PORTE = 0;
7       while(1);              // Endless loop
8                              // While Button is held, the onboard LED will blink according to ON/OFF timer
9                              // For example, connect beeper from digital multimeter on terminal
10     }

Downloads

 mikroBUS™ Standard specification 

 LibStock: FLICKER click Examples 

 FLICKER click Schematic

Related links to "FLICKER click"
Read, write and discuss reviews...more
Customer evaluation for "FLICKER click"
Write a review
Reviews will be activated after verification.

The fields marked with * are required.

Viewed